ACL6/3/PKTFLT_BUDRUN_FAIL:Failed to buildrun packet filter!

Description

Failed to generate configuration information on packet filtering.

Parameters

Parameter Name Parameter Meaning
None None

Possible Causes

ACL resources were insufficient.

Procedure

  1. Run the display memory-usage command to check whether the memory usage of the switch exceeds 85%.

    • If so, go to step 2.
    • If not, go to step 4.

  2. Run the display acl all command to view configurations of all ACLs. Check whether redundant ACLs are configured.

    • If so, run the undo acl ipv6 command in the system view to delete the redundant configurations, and go to step 3.
    • If not, go to step 4.

  3. Check whether configuration information can be generated.

    • If so, no further action is required.
    • If not, go to step 4.

  4. Collect log information and configuration information, and then contact technical support personnel. You can collect diagnostic information using the display diagnostic-information command.