< Home

ACL6/4/RPC_FAILED

Message

ACL6/4/RPC_FAILED:Failed to call synchronization IPC! (ErrorCode= [ULONG])

Description

Failed to call synchronization IPC.

Parameters

Parameter Name Parameter Meaning
ErrorCode Indicates the error codes, including the following:

2: indicates that memory allocation for sending messages failed.

3: indicates that synchronizing IPC timed out.

4: indicates that message waiting queue overflowed.

Possible Causes

When the ACL6 module sends information, the RPC failed to call functions.

Procedure

  1. Run the display device command to check whether the member switch has registered.

    • If so, go to step 3.
    • If not, go to step 2.

  2. If the member switch has not registered, RPC communication fails, which is normal. This log is informational only, and no action is required.
  3. Collect log information about RPC message sending failures of the member switch, and contact technical support personnel. You can collect diagnostic information using the display diagnostic-information command.
Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic