SRM/3/NAND_BADBLOCK_FAIL

Message

SRM/3/NAND_BADBLOCK_FAIL: The bad block ratio in partion [STRING1] exceeded threshold. (Threshold=[STRING2], CurrentValue=[STRING3])

Description

The bad block rate of the NVRP partition exceeded the threshold 1.5%.

Parameters

Parameter Name Parameter Meaning
STRING1 Indicates the partition name.
STRING2 Indicates the bad block rate threshold 1.5%.
STRING3 Indicates the current bad block rate.

Possible Causes

The NVRP partition was read and written frequently, leading to the storage component loss.

Procedure

  1. Restart the device. Ten seconds later, check whether the log persists.
    • If not, no action is required, and the log handling ends.
    • If so, go to step 2.
  2. Run the format flash: command to format the flash. Ten seconds later, check whether the log is cleared.
    • If not, no action is required, and the log handling ends.
    • If so, go to step 3.
  3. Contact technical support personnel to replace the device or flash component.