ASMNG_1.3.6.1.4.1.2011.5.25.327.31.2.2.5 hwAsPortStateChangeToDownNotify

Description

ASMNG/4/ASPORTSTATEDOWN: OID [oid] AS interface turned into DOWN state. (AS Index=[INTEGER], AS IfIndex=[INTEGER], AS Name=[STRING], Slot Model=[STRING], AS MAC=[OPAQUE], Interface=[STRING], ifAdminStatus=[INTEGER], ifOperStatus=[INTEGER])

An AS port went Down.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.327.31.2.2.5 Warning processingErrorAlarm(4)

Parameters

Name Meaning
oid Indicates the MIB object ID of the alarm.
AS Index Indicates the AS index.
AS IfIndex Indicates the index of the port.
AS Name Indicates the AS name.
Slot Model Indicates the AS model.
AS MAC Indicates the MAC address of the AS.
Interface Indicates the port name.
ifAdminStatus Indicates the administrative status of the port.
ifOperStatus Indicates the operating status of the port.

Impact on the System

Services on the port are interrupted.

Possible Causes

Cause 1: A link failure occurred on the port.

Cause 2: The port was shut down manually.

Procedure

  1. Check whether the AS port was shut down manually, for example, whether the shutdown command was executed on this port or its cable was removed.

    • If so, the alarm handling ends.

    • If not, go to step 2.

  2. Replace the cable and optical module of this port to determine whether the existing cable or optical module is faulty.

    • If so, replace the existing cable or optical module.

    • If not, collect alarm information and configuration information, and then contact technical support personnel.