ASMNG/3/SAVE_PSK_FAIL: Failed to save the pre-shared key.
Description
The AS failed to save the pre-shared key to the flash memory.
Parameters
Parameter Name
Parameter Meaning
None
None
Possible Causes
The AS failed to save the pre-shared key to the flash memory.
Procedure
Enable the AS to save the pre-shared key to the flash memory again after this AS is restarted. For details about restarting an AS, see "Restarting an AS" in the S2720, S5700, and S6700V200R019C10 Configuration Guide - Device Management Configuration - SVF Configuration.
If the fault persists, a flash failure occurred. Replace this AS. For details, see "Replacing an AS" in the S2720, S5700, and S6700V200R019C10 Configuration Guide - Device Management Configuration - SVF Configuration.
If the fault persists after this AS is replaced, collect log information and configuration information, and then contact technical support personnel.You can collect diagnostic information using the display diagnostic-information command.