BASETRAP/1/ENTITYDYINGGASP: OID [OID] Dying Gasp event is occurred. (MacAddress="[OCTET]", ReasonCode="[INTEGER]", ReasonDescription="[OCTET]")
The device is powered off.
Alarm ID | Alarm Severity | Alarm Type |
---|---|---|
1.3.6.1.4.1.2011.5.25.129.2.1.19 |
Critical |
equipmentAlarm(5) |
Name | Meaning |
---|---|
OID |
Indicates the MIB object ID of the alarm. |
MacAddress |
Indicates the MAC address of the device. |
ReasonCode |
Indicates the code of the alarm cause. |
ReasonDescription |
Indicates the description of the alarm cause. |
Cause 1: The power cable connected to the device is loose.
Cause 2: The external power line is faulty.
Cause 3: The power module of the device has failed.
In a stack, if the master switch is powered off, this alarm will be generated and the NMS will receive dying gasp packets. If the standby or slave switch is powered off, this alarm will not be generated and the NMS will not receive dying gasp packets because there is no information in the routing table of the standby or slave switch.