EFM/4/LOOPBACKFAIL:OID [OID] Interface starts loopback failed. (IfIndex=[INTEGER],IfName=[STRING])
802.3ah loopback failed after no response to an 802.3ah loopback request was received within a specified period of time.
Alarm ID | Alarm Severity | Alarm Type |
---|---|---|
1.3.6.1.4.1.2011.5.25.136.1.6.29 |
Warning |
qualityOfServiceAlarm (3) |
Name | Meaning |
---|---|
oid |
Indicates the MIB object ID of the alarm. |
IfIndex |
Interface index |
IfName |
Interface name |
802.3ah loopback failed after no response to an 802.3ah loopback request was received within a specified period of time.
Run the display current-configuration command. Check whether the efm loopback ignore-request command is used.
If this command is used, the remote interface denies the request. Run the undo efm loopback ignore-request command to enable the remote interface to receive the remote loopback request. Then go to Step 2.
If this command is not used, the remote interface is able to receive the request. Then go to Step 3.
Run the display efm session all command. Check whether the value of the EFM State field is detect.