< Home

ENTITYTRAP_1.3.6.1.4.1.2011.5.25.219.2.5.11 hwIntegratedPowerFault

Description

ENTITYTRAP/1/INTPOWERFAULT:OID [oid] Integrated power failure. (Index=[INTEGER], EntityPhysicalIndex=[INTEGER], PhysicalName="[OCTET]", EntityTrapFaultID=[INTEGER], EntityTrapReasonDescr="[OCTET]")

The built-in power supply is faulty.

Attribute

Alarm ID Alarm Severity Alarm Type

1.3.6.1.4.1.2011.5.25.219.2.5.11

Critical

equipmentAlarm(5)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

Index

Indicates the index.

EntityPhysicalIndex

Indicates the index of the physical entity.

PhysicalName

Indicates the name of a physical entity.

EntityTrapFaultID

Indicates the error code.

EntityTrapReasonDescr

Indicates the alarm reason.

Impact on the System

The built-in power supply is unavailable.

Possible Causes

Error Code

Alarm Reason

Description

153856

AC power failure.

-

153857

AC surge protector failure.

-

153858

Solar-cell subarray group fault.

-

153859

Module upgrade failed.

-

153860

12 V DC output protection.

-

153861

24 V AC output protection.

-

153862

53 V DC output protection.

-

153863

Load low voltage disconnection (LLVD).

-

Procedure

  1. Collect log information and configuration information, and then contact technical support personnel.You can collect diagnostic information using the display diagnostic-information command.
Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >