EOAM1AG/1/LOC: OID [oid] MEP is disconnected with the remote MEP. (MdIndex=[GAUGE], MaIndex=[GAUGE], MdName=[STRING], MaName=[STRING], MepId=[INTEGER], RmepId=[INTEGER])
The MEP received no CCM in a period of time 3.5 times the interval at which CCMs were sent.
Alarm ID | Alarm Severity | Alarm Type |
---|---|---|
1.3.6.1.4.1.2011.5.25.136.1.6.42 | Critical | communicationsAlarm(2) |
Name | Meaning |
---|---|
oid |
Indicates the MIB object ID of the alarm. |
MdIndex |
Index of an MD table |
MaIndex |
Index of an MA table |
MdName |
Name of an MD |
MaName |
Name of an MA |
MepId |
ID of a MEP |
RmepId |
ID of an RMEP |
If this alarm is displayed, the link CC check fails, CCM configuration is incorrect, or a physical link fails.
The MEP received no CCM in a period of time 3.5 times the interval at which CCMs were sent.
Run the display cfm mep [ md md-name [ ma ma-name [ mep-id mep-id ] ] ] command to view the value of the Interface Name field. Obtain the interface type and number.
Run the display interface interface-type interface-num command with the obtained interface type and number specified. View the value of the current state field.
If the value of the current state field is Up, go to Step 2.
If the value of the current state field is not Up, the interface connection fails. For the troubleshooting procedure, see "Physical Interconnection Troubleshooting."