< Home

EZOP/3/PROCESS_STOP

Message

EZOP/3/PROCESS_STOP: Easy-operation upgrade process has been stopped. (Reason=[STRING])

Description

An EasyDeploy upgrade has stopped.

Parameters

Parameter Name Parameter Meaning
[STRING] Indicates the reason why the upgrade process stops.

Possible Causes

The reasons why an EasyDeploy upgrade stops include but not limit to the following:

  • 1: The device detects inputs on the serial port.
  • 2: The device is upgrading using a USB flash drive.

Procedure

  • If reason 1 is displayed, stops the operation on the serial port and restart the EasyDeploy upgrade process. No input is allowed on the serial port during an EasyDeploy upgrade process.
  • If reason 2 is displayed, select either EasyDeploy upgrade or USB-based upgrade.
Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.