< Home

ENTITYTRAP_1.3.6.1.4.1.2011.5.25.219.2.4.19 hwOpticalBiasCurrentAlarm

Description

ENTITYTRAP/3/OPTBIASCURALM: OID [oid] The bias current exceeds the upper alarm threshold or falls below the lower alarm threshold. (Index=[INTEGER], EntityPhysicalIndex=[INTEGER], PhysicalName="[OCTET]", EntityTrapFaultID=[INTEGER], EntityTrapReasonDescr="[OCTET]")

The bias current of the laser on an optical module is higher than the upper alarm threshold or lower than the lower alarm threshold.

Attribute

Alarm ID Alarm Severity Alarm Type

1.3.6.1.4.1.2011.5.25.219.2.4.19

Minor

equipmentAlarm(5)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

Index

Indicates an index.

EntityPhysicalIndex

Indicates the index of the physical entity.

PhysicalName

Indicates the entity name.

EntityTrapFaultID

Indicates the error code.

  • 153088 indicates that the bias current of the laser on an optical module exceeds the upper alarm threshold.
  • 153089 indicates that the bias current of the laser on an optical module is lower than the lower alarm threshold.

EntityTrapReasonDescr

Indicates the alarm reason.

Impact on the System

If the bias current of the laser on an optical module is too low, the gain is insufficient. If the bias current is too high, the laser is damaged and even services are interrupted.

Possible Causes

Cause 1: The laser on the optical module is aged.

Cause 2: The card is faulty.

Procedure

  1. Replace the optical module of the port that reports the alarm or the card that reports the alarm.
Copyright © Huawei Technologies Co., Ltd.