< Home

ENTITYTRAP_1.3.6.1.4.1.2011.5.25.219.2.5.1 hwPowerRemove

Description

ENTITYTRAP/4/POWERREMOVE: OID [oid] Power is absent. (Index=[INTEGER], EntityPhysicalIndex=[INTEGER], PhysicalName="[OCTET]", EntityTrapFaultID=[INTEGER])

The power supply was removed.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.219.2.5.1 Warning equipmentAlarm(5)

Parameters

Name Meaning
oid Indicates the MIB object ID of the alarm.
Index Indicates the index.
EntityPhysicalIndex Indicates the index of the physical entity.
PhysicalName Indicates the name of the physical entity.
EntityTrapFaultID Indicates the error code: 136448.

Impact on the System

Some boards cannot work properly due to lack of power.

Possible Causes

The power supply was removed.

Procedure

  1. Check whether the power module is installed in the slot.

    • If so, go to step 2.
    • If not, install the power module in the slot.

  2. Run the display device command to check whether the power module is working properly.

    • If so, but the alarm persists, replace the power module.
    • If not, install the power module securely.

Copyright © Huawei Technologies Co., Ltd.