ENTITYTRAP/1/POWERINVALID: OID [oid] Power supply is unavailable for some reason. (Index=[INTEGER], EntityPhysicalIndex=[INTEGER], PhysicalName="[OCTET]", EntityTrapFaultID=[INTEGER])
The device experienced a complete failure of power supply.
Alarm ID | Alarm Severity | Alarm Type |
---|---|---|
1.3.6.1.4.1.2011.5.25.219.2.5.5 |
Critical |
equipmentAlarm(5) |
Name | Meaning |
---|---|
oid |
Indicates the MIB object ID of the alarm. |
Index |
Indicates the index. |
EntityPhysicalIndex |
Indicates the index of the physical entity. |
PhysicalName |
Indicates the name of a physical entity. |
EntityTrapFaultID |
Indicates the error code. |
Error Code |
Possible Causes and Impact on the System |
Procedure |
---|---|---|
136961 |
The power module does not work properly. The device may be powered off because of power insufficiency. |
Rectify the fault according to A Power Module Cannot Provide Power in the Troubleshooting Insights-Campus Switch-Hardware Fault. |
136966 |
The power supply was installed but not powered on or the power module has failed. The device may be powered off because of power insufficiency. |
Rectify the fault according to A Power Module Cannot Provide Power in the Troubleshooting Insights-Campus Switch-Hardware Fault. |
136969 |
|
Rectify the fault according to A Power Module Cannot Provide Power in the Troubleshooting Insights-Campus Switch-Hardware Fault. |
136972 |
The PoE power module is not supported by the device. The PoE function does not take effect, and powered devices (PDs) cannot be powered on. |
Replace the power module with a PoE power module supported by the device. Currently, PoE power modules supported by a switch include 800 W AC, 2200 W AC, and 2200 W DC power modules. |
136973 |
A power module providing mismatching power is installed on the device. For example, a 150 W power module is installed on the S5720-HI. |
Replace the current power module with a power module providing matching power. |
136984 |
The RPS 12 V power supply is abnormal. The RPS power supply is present but has no output power and so is unavailable. |
Replace the RPS power supply. |
136993 |
The secondary power supply is abnormal. |
Collect alarm information and configuration information, and then contact technical support personnel. |
136994 |
The AVS power supply is partially short-circuited. |
Collect alarm information and configuration information, and then contact technical support personnel. |