FSP/3/PORTERRDOWN: OID [OID] STACK port [STRING] trigger error down. (ErrorDownType=[STRING])
An error-down event occurred on a stack port.
Alarm ID | Alarm Severity | Alarm Type |
---|---|---|
1.3.6.1.4.1.2011.5.25.183.1.22.59 | Minor | communicationsAlarm (2) |
Name | Meaning |
---|---|
OID | Indicates the MIB object ID of the alarm. |
STACK port | Indicates the local port name. |
Error down type | Indicates the error-down event type. |
Cause 1: The stack port receives CRC error packets.
Cause 2: The stack port frequently alternates between Up and Down states.
Cause 3: The rate of the optical module installed in the port is different from the rate of the port.
If the reason is Link-flapping trigger error down, rectify the fault according to An Ethernet Interface Frequently Alternates Between Up and Down States.
If the reason is CRC trigger error down or Runts trigger error down, go to step 2.
If the reason is Media mismatch trigger error down, go to step 4.
If so, go to step 3.
If not, the alarm handling ends.
If so, collect alarm information and configuration information, and then contact technical support personnel.
If not, the alarm handling ends.
If so, Collect alarm information and configuration information, and then contact technical support personnel.
If not, the alarm handling ends.