FSP/4/STACK_RESTART: OID [oid] After stack restart, the new master is slot [integer].
This alarm was sent to the NMS by the master switch after all the switches in the stack system were restarted.
Alarm ID | Alarm Severity | Alarm Type |
---|---|---|
1.3.6.1.4.1.2011.5.25.183.1.22.5 | Warning | equipmentAlarm(5) |
Name | Meaning |
---|---|
oid | Indicates the MIB object ID of the alarm. |
[integer] | Stack ID of the device generating the alarm. |
During the restart of the stack system, services are interrupted. After the restart of the stack system, services recover.
1. The reboot command was manually run on the master switch to restart the stack system.
2. The master and standby switches in the stack system were powered off at the same time.
3. All the switches in the stack system were powered off at the same time.
If so, the alarm handling ends.
If not, go to step 2.
If so, the alarm handling ends.
If not, collect alarm information and configuration information, and then contact technical support personnel.