FSP_1.3.6.1.4.1.2011.5.25.183.1.22.61 hwStackSetUpFailure

Description

FSP/3/SETUPFAILURE: OID [OID] Failed to set up a stack. (LocalSlotID=[integer], PeerSlotID=[integer], Reason=[STRING])

A stack fails to be set up.

Attribute

Alarm ID Alarm Severity Alarm Type

1.3.6.1.4.1.2011.5.25.183.1.22.61

Minor

communicationsAlarm (2)

Parameters

Name Meaning

OID

Indicates the MIB object ID of the alarm.

LocalSlotID

Indicates the slot ID of the local stack member switch.

PeerSlotID

Indicates the slot ID of the remote stack member switch.

Reason

Indicates the reason why the stack fails to be set up.

Impact on the System

Services cannot run normally.

Possible Causes

  • The switches cannot set up a stack because of a device model mismatch.
  • The switches cannot set up a stack because ports on a dedicated stack card are connected to service ports.

Procedure

  1. Check whether ports on a dedicated stack card are connected to service ports on the panel or a service card.
    • If so, change the connections.
    • If not, go to step 2.
  2. Run the display device command to check the switch model.
  3. Use switches of the same model or different models that allow to set up a stack together based on Stack Support and Version Requirements.