HSC/4/SICTMP_EXCD_HGTHR: Temperature of SIC in slot [ULONG] exceeds the high threshold.
Description
The equipment temperature has exceeded the upper threshold.
Parameters
Parameter Name
Parameter Meaning
ULONG
Indicates a slot ID.
Possible Causes
Cause 1: The environment temperature is high.
Cause 2: Fans in the switch are not running.
Procedure
Reduce the environment temperature and check whether the log persists.
If so, go to step 2.
If not, the fault has been rectified.
Clean or replace fans of the device and check whether the log persists.
If so, go to step 3.
If not, the fault has been rectified.
Check whether the device temperature is within the acceptable range.
If so, run the temperature threshold command to change the temperature alarm threshold.
If not, go to step 4.
Collect log information and configuration information, and then contact technical support personnel.You can collect diagnostic information using the display diagnostic-information command.