< Home

IFNET_1.3.6.1.4.1.2011.5.25.41.4.9 hwIfMonitorHalfduplexRising

Description

IFNET/1/HALFDUPLEXRISING: OID [oid] The work mode is half duplex. (hwIfMonitorIndex=[INTEGER])

The trap is generated when the interface works in half-duplex mode.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.41.4.9 Critical other(1)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

hwIfMonitorIndex

Indicates the physical index.

Impact on the System

Packets may be dropped when the interface works in half-duplex mode.

Possible Causes

The electrical interface worked in half-duplex mode.

Procedure

  1. You can set the interface to work in full duplex mode by the duplex full command.

Related Information

None.