Description

IFPDT/3/TUNNELIFNUMOVERSPEC:OID [OID] The number of Tunnel interfaces exceeds the limit. (TunnelIfThreshold=[INTEGER], CurrentNum=[INTEGER])

The number of tunnel interfaces exceeded the upper limit.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.157.2.305 Warning equipmentAlarm(5)

Parameters

Name Meaning
OID Indicates the MIB object ID of the alarm.
TunnelIfThreshold Maximum number of tunnel interfaces.
CurrentNum Number of tunnel interfaces that have been created.

Impact on the System

If the number of tunnel interfaces that have been created exceeds the TunnelIfThreshold value, other services may fail to apply for the memory.

Possible Causes

The alarm is triggered if the number of tunnel interfaces that have been created exceeds the TunnelIfThreshold value.

Procedure

  1. You can run the undo interface tunnel command in the system view to delete some tunnel interfaces to make the total number of tunnel interfaces not exceed the TunnelIfThreshold value.