< Home

L2V_1.3.6.1.4.1.2011.5.25.119.1.2.9 hwVplsVcNumberThresholdExceed

Description

L2V/3/VPLSVC_THRESHOLD_EXCEED_T:OID [OID] The number of VPLS VCs reaches the upper threshold. (LimitClass=[INTEGER], CurrentVcNumber=[GAUGE], UpperThreshold=[GAUGE], MaxiVcNumber=[GAUGE])

The proportion of VPLS VCs created to the maximum VPLS VCs allowed reached the upper alarm threshold.

Attribute

Alarm ID Alarm Severity Alarm Type

1.3.6.1.4.1.2011.5.25.119.1.2.9

Minor

qualityOfServiceAlarm

Parameters

Name Meaning

OID

Indicates the MIB object ID of the alarm.

LimitClass

Limit type

CurrentVcNumber

Number of VPLS VCs created

UpperThreshold

Upper alarm threshold

MaxiVcNumber

Maximum number of VPLS VCs allowed

Impact on the System

Services will not be affected.

Possible Causes

The proportion of VPLS VCs created to the maximum VPLS VCs allowed reached the upper alarm threshold.

Procedure

  1. Run the display vpls connection command to check the number of configured VPLS VCs. Reduce the number of VPLS VCs created to prevent device performance deterioration.
Copyright © Huawei Technologies Co., Ltd.