< Home

L2V/5/VPLSVC_UP_ME

Message

L2V/5/VPLSVC_UP_ME:The status of the VPLS VC turned UP. (VsiName=[STRING], RemoteIp=[IPADDR], PwId=[ULONG], Reason=[STRING], SysUpTime=[TIMETICK])

Description

This log message explained why the VPLS VC interface went Up.

Parameters

Parameter Name Parameter Meaning
VsiName Indicates the name of the Virtual Switching Instance (VSI).
RemoteIp Indicates the IP address of the remote end.
PwId Indicates the ID of the pseudo wire (PW).
Reason Indicates the cause:

1. Invalid reason type

2. VC was created

3. VC was deleted

4. LDP session was Down

5. LDP session was Up

6. Same LDP mapping was received with different label and MTU

7. Same LDP mapping was received with matching interface parameters

8. LDP mapping was received with mismatching interface parameters

9. LDP mapping was received with unpass Cbit check

10. LDP mapping was received with unpass PW loop check

11. New LDP mapping was received

12. New LDP mapping was received but remote Vc or local Vc is Down

13. LDP withdrawn message was received

14. LDP release message was received

15. LDP request message was received

16. LDP GR ended processing

17. RSVP message was received

18. Interface was Up

19. Interface was Down

20. Interface encapsulation changed

21. Refresh

22. Download again

23. Tunnel was Up

24. Tunnel was Down

25. VC state changed when New RLB was received

26. RLB was Deleted

27. VC was created or connected to another remote CE

28. Outgoing interface was unavailable

29. Outgoing interface was available

30. LDP notification message was forwarded

31. LDP notification message was not forwarded

32. PW was recreated

33. Download FTN & ILM for Eth-Trunk

34. AC OAM fault detection was disabled

35. Remote AC fault

36. Remote AC fault was resumed

37. Local AC fault

38. Local AC fault was resumed

39. Remote PSN fault

40. Remote PSN fault was resumed

41. Local PSN fault

42. Local PSN fault was resumed

43. BFD for PW status changed to Down

44. BFD for PW status changed to Up

45. BFD for PW status changed to ADMIN DOWN

46. BFD for PW was disabled

47. Manual set was enabled

48. Manual set was disabled

49. Delay timed out

50. Resume timed out

SysUpTime Indicates the Tick time for the system being Up.

Possible Causes

The VC went Up.

Procedure

  1. Identify the cause of the VC status change.