LACP_1.3.6.1.4.1.2011.5.25.41.3.34 hwLacpPartnerExpiredLoss

Description

LACP/2/PEL:OID [oid] The member of LAG receive expired PDU from partner. (TrunkIndex=[INTEGER], PortIfIndex=[INTEGER], TrunkId=[INTEGER], TrunkName=[OCTET], PortName=[OCTET])

The local end received a timeout packet from the remote end.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.41.3.34 Major other(1)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

TrunkIndex

Index of an Eth-Trunk interface in static LAC mode

PortIfIndex

Index of an Eth-Trunk member interface in static LAC mode

TrunkId

ID of an Eth-Trunk interface in static LAC mode

TrunkName

Name of an Eth-Trunk interface in static LAC mode

PortName

Name of an Eth-Trunk member interface in static LAC mode

Impact on the System

Partial or all link bandwidth will lose, causing partial or all services to be interrupted.

Possible Causes

The remote end could not receive the LACP packet from the local end.

Procedure

  • If both local and remote ends are Huawei Datacom devices, see the troubleshooting procedures in LACP_1.3.6.1.4.1.2011.5.25.41.3.2 hwLacpNegotiateFailed.
    1. Check whether the interface is Down.

      • If so, go to Step 2.

      • If not, go to Step 4.

    2. Run the undo shutdown command to check whether the alarm is cleared.

      • If the alarm is cleared, go to Step 8.

      • If the alarm is not cleared, go to Step 3.

    3. Check whether the physical link is faulty.

      • If so, go to Step 6.

      • If not, go to Step 4.

    4. Check whether there is an interface on the local or remote end of the link leaving the LAG.

      • If so, go to Step 5.

      • If not, go to Step 7.

    5. Check whether the interface leaves the LAG normally.

      • If so, go to Step 8.

      • If not, go to Step 7.

    6. Repair the physical link and then check whether the alarm is cleared.

      • If the alarm is cleared, go to Step 8.

      • If the alarm is not cleared, go to Step 4.

    7. Collect alarm information and configuration information, and then contact technical support personnel.
    8. End.