LDP/4/IMPMSGLISTEXCEED

Message

LDP/4/IMPMSGLISTEXCEED:The length of the LDP important message list reached the alarm threshold [threshold].

Description

The length of the LDP important message list reached the alarm threshold.

Parameters

Parameter Name Parameter Meaning
[threshold] Indicates the alarm threshold of the LDP message list.

Possible Causes

After a large number of LDP messages were received, these messages were not processed in time, causing the queue length to the alarm threshold.

Procedure

  1. Run the display memory-usage command to check memory usage.
  2. If necessary and allowed, run the reset mpls ldp command in the user view to clean the linked list. Exercise caution when running this command because all LDP sessions will be reset.
  3. Collect log information and configuration information, and then contact technical support personnel.
Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.