Description

LSPM/2/MPLSTEAUTOTUNNELDOWNCLEAR:OID [oid] The TE Auto tunnel Down alarm was cleared. (SessionTunnelId=[integer], LocalLspId=[integer], IngressLsrId=[integer], EgressLsrId=[integer], mplsTunnelAdminStatus=[integer], mplsTunnelOperStatus=[integer], mplsTunnelIfName=[octet])

The TE Auto tunnel Down alarm was cleared.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.121.2.1.54

Major

communicationsAlarm(2)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

SessionTunnelId

Indicates the ID of the tunnel.

LocalLspId

Indicates the ID of local LSP.

IngressLsrId

Indicates the ID of the ingress LSR.

EgressLsrId

Indicates the ID of the egress LSR.

mplsTunnelAdminStatus

Indicates the administration status of the tunnel.

mplsTunnelOperStatus

Indicates the operating status of the tunnel.

mplsTunnelIfName

Indicates the name of the tunnel interface.

Impact on the System

Services will not be affected.

Possible Causes

The TE Auto tunnel was created successfully.

Procedure

  • This trap message is informational only, and no action is required.

Related Information

None.