MBR_1.3.6.1.4.1.2011.5.25.327.31.6.2.10.1 hwASMadConflictDetect

Description

MBR/4/ASMULATVDETECT: OID [oid] Multi-active scenario is detected. (ASName=[OCTET], ASIndex=[INTEGER])

A multi-active fault occurred.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.327.31.6.2.10.1 Warning equipmentAlarm(5)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.
ASName Indicates the AS name.
ASIndex Indicates the AS index.

Impact on the System

Multiple switches with the same IP address, MAC address, and global configuration exist on the network. As a result, an address conflict occurs.

Possible Causes

The stack link failed.

Procedure

  1. Obtain the name of the AS where the fault occurred. In the alarm, ASName indicates the AS name.
  2. Check whether the stack cable of the AS is loose. If so, reconnect the stack cable securely. If the corresponding clear alarm is not generated, replace the stack cable.
  3. Check whether the corresponding clear alarm is generated. If so, no action is required. If not, go to step 4.
  4. Collect alarm information and configuration information, and then contact technical support personnel.