OPSA/3/OPS_SNMP_CONDITION_NEXT_FAIL

Message

OPSA/3/OPS_SNMP_CONDITION_NEXT_FAIL: Failed to obtain the next MIB object using the script. (Script="[script-name]", current MIB object="[object]")

Description

Failed to obtain detailed information about the next object for a leaf object with the specified OID a user script in the subscription phase.

Parameters

Parameter Name Parameter Meaning
[script-name] Indicates a user script name.
[object] Indicates a MIB object.

Possible Causes

In the subscription phase of the user script, parameters of the Obtaining Device Information Through SNMP (getnext) API (ops.snmp.getnext) are incorrect or the OID does not exist.

Procedure

  1. In the subscription phase of the user script, parameters of the Obtaining Device Information Through SNMP (getnext) API (ops.snmp.getnext) are incorrect or the OID does not exist (For how to obtain the MIB object OID, see S2720, S5700, and S6700 V200R019C10 MIB Reference). You need to modify the script.