< Home

OPSA/3/OPS_SNMP_EXECUTE_NEXT_FAIL

Message

OPSA/3/OPS_SNMP_EXECUTE_NEXT_FAIL: Failed to obtain the next MIB object using the script. (Script="[script-name]", event="[event-name]", instance=[instance-id], current object="[object]")

Description

Failed to obtain detailed information about the next object for a leaf object with the specified OID a user script in the execution phase.

Parameters

Parameter Name Parameter Meaning
[script-name] Indicates a user script name
[event-name] Indicates an event name.
[instance-id] Indicates an instance ID.
[object] Indicates a MIB object.

Possible Causes

In the execution phase of the user script, parameters of the Obtaining Device Information Through SNMP (getnext) API (ops.snmp.getnext) are incorrect or the OID does not exist.

Procedure

  1. In the execution phase of the user script, parameters of the Obtaining Device Information Through SNMP (getnext) API (ops.snmp.getnext) are incorrect or the OID does not exist (For how to obtain the MIB object OID, see S2720, S5700, and S6700 V200R019C10 MIB Reference). You need to modify the script.