< Home

PKI_1.3.6.1.4.1.2011.6.122.34.0.2.15 hwPKICrlInvalid

Description

PKI/2/PKICRLINVALID: OID [oid] the crl is invalid. (CrlIssuer=[crlissuer], CrlStartTime=[crlstarttime], CrlFinishTime=[crlfinishtime])

The CRL is invalid.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.6.122.34.0.2.15 Major communicationsAlarm

Parameters

Name Meaning
oid Indicates the MIB object ID of the alarm.
crlissuer Indicates the issuer of the CRL.
crlstarttime Indicates the start time of the CRL.
crlfinishtime Indicates the end time of the CRL.

Impact on the System

The service becomes invalid.

Possible Causes

Indicates that the current system time is out of the CRL validity period.

Procedure

  1. Run the display clock command to check whether the device time is correct.

    If not, run the clock datetime command in the user view to change the device time.

  2. Obtain a new CRL. For details, see "Configuring Local Certificate Check" in S2720, S5700, and S6700 V200R019C10 Configuration Guide - PKI Configuration.
Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.