< Home

PKI/4/CRL_VALID

Message

PKI/4/CRL_VALID: CRL ([issuer_name]) will be valid in [day] days.

Description

A CRL was invalid.

Parameters

Parameter Name Parameter Meaning

issuer_name

Specifies the name of the CRL issuer.

day

Specifies the number of days before the CRL takes effect.

Possible Causes

The system time of the device does not reach the start time of the CRL validity period.

Procedure

  1. Run the display clock command to check whether the system time of the device is correct.

    • If not, run the clock datetime command in the user view to change the system time of the device.
    • If so, go to step 2.

  2. Collect required information and contact technical support personnel.