POE/4/POWEROFF: OID [oid] PD powered off. (IfIndex=[INTEGER], Interface="[OCTET]")
The PD connected to the interface is powered off.
Alarm ID | Alarm Severity | Alarm Type |
---|---|---|
1.3.6.1.4.1.2011.5.25.195.40.2 | Warning | communicationsAlarm(2) |
Name | Meaning |
---|---|
oid | Indicates the MIB object ID of the alarm. |
IfIndex | Indicates the interface index. |
Interface | Indicates the interface name. |
1. The PD is removed.
2. The PD is faulty.
3. When the power is insufficient, the interface with a higher priority preempts the power.
4. The interface to which the PD connects is automatically powered off in the power-off time range.
5. The PD is powered off because of overcurrent protection.
If so, go to step 2.
If not, go to step 4.
If so, the alarm handling ends.
If not, go to step 3.
If so, the alarm handling ends.
If not, go to step 4.
If so, go to step 5.
If not, connect the PD to another interface or PoE device.
If so, go to step 6.
If not, go to step 8.
If so, go to step 6.
If not, go to step 7.
If so, the alarm handling ends.
If not, go to step 8.
If so, the alarm handling ends.
If not, go to step 9.
If so, replace it.
If not, collect alarm information and configuration information, and then contact technical support personnel.