PTP_1.3.6.1.4.1.2011.5.25.187.5.37 hwPtpTimeOffsetSumOver

Description

PTP/3/PTPTIMEOFFSETSUMOVER:OID [oid] The ptp time offset sum is abnormal.(hwPtpTimeOffsetSumP2P=[integer], hwPtpAlarmThresholdOffsetSum=[integer]).

The PTP time offset sum exceeded the threshold.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.187.5.37 Minor equipmentAlarm(5)

Parameters

Name Meaning
[oid] Indicates the MIB object ID of the alarm.

hwPtpTimeOffsetSumP2P

Peak-to-peak time offset sum of the clock source

hwPtpAlarmThresholdOffsetSum

Alarm threshold for the time offset sum

Impact on the System

The involved device fails to lock the time source.

Possible Causes

The peak-to-peak time offset accumulated within 15 minutes exceeded the threshold.

Procedure

  1. Run the display ptp all command to check whether the current time is clocked.

    • If so, go to Step 3.
    • If not, go to Step 2.

  2. Wait for 5 minutes. Run the display ptp all command to check whether the time is locked.

    • If so, go to Step 3.
    • If not, go to Step 4.

  3. Wait for 5 minutes. Check whether the alarm is cleared.

    • If the alarm is cleared, go to Step 5.
    • If the alarm persists, go to Step 4.

  4. Collect trap, log, and configuration information, and contact Huawei technical support personnel.
  5. End.