< Home

RM/4/RT_NUM_EXCD_WARN

Message

RM/4/RT_NUM_EXCD_WARN:The number of routes in [vpn-instance-name] was [current-number], which exceeded the alarm threshold [threshold-value]. (InstanceId=[ULONG], MaximumRouteLimit=[ULONG])

Description

The number of routes in a specific VPN instance reached or exceeded the alarm threshold of this VPN instance.

Parameters

Parameter Name Parameter Meaning
[vpn-instance-name] Indicates the name of a VPN instance.
[threshold-value] Indicates the value of the alarm threshold.
InstanceId Indicates the ID of a VPN instance.
MaximumRouteLimit Indicates the maximum number of routes.

[current-number]

Indicates the actual number of routes.

Possible Causes

The number of routes in a specific VPN instance reached or exceeded the alarm threshold of this VPN instance.

Procedure

  1. Run the display ip routing-table [ vpn-instance vpn-instance-name ] statistics command to check the total number and types of routes in this VPN instance.
  2. Analyze the source of each route and check whether the number of current routes in the VPN instance meets the actual requirement.

    • If so, go to Step 4.
    • If not, go to Step 3.

  3. Delete unnecessary private routes, and then check whether the number of routes still reaches or exceeds the alarm threshold.

    • If so, go to Step 5.
    • If not, go to Step 6.

  4. Enter the VPN instance view and run the display this command to check the configuration of routing-table limit to check whether the set alarm threshold of private routes is proper.

    • If so, go to Step 5.
    • If not, run the routing-table limit number { alert-percent | simply-alert } command to reconfigure a proper alarm threshold. Then, go to Step 6.

  5. Collect log information and configuration information, and then contact technical support personnel.
  6. End.
Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >