SRM/3/ENTITYOFFLINE: OID [OID] fan pull out. (EntityPhysicalIndex[INTEGER1], BaseTrapSeverity=[INTEGER2], BaseTrapProbableCause=[INTEGER3], BaseTrapEventType=[INTEGER4], EntPhysicalContainedIn=[INTEGER5], EntPhysicalName=[OCTET1], RelativeResource=[OCTET2], ReasonDescription=[OCTET3])
This alarm was generated when the fan module was removed.
Alarm ID | Alarm Severity | Alarm Type |
---|---|---|
1.3.6.1.4.1.2011.5.25.129.2.1.13 | Minor | equipmentAlarm(5) |
Name | Meaning |
---|---|
OID | Indicates the MIB object ID of the alarm. |
EntityPhysicalIndex | Entity index. |
BaseTrapSeverity | Severity code. |
BaseTrapProbableCause | Error code. |
BaseTrapEventType | Code of the event type. |
EntPhysicalContainedIn | Entity code. |
EntPhysicalName | Entity name. |
RelativeResource | Name of the affected component. |
ReasonDescription | Fault description. |
After the fan module is removed, the temperature of the board increases, which may result in faults on the device. That is, packet loss may occur or even more seriously, the device may be suspended or abnormally reset.
If so, go to step 2.
If not, install the fan subcard and the alarm handling ends.
If so, the alarm handling ends.
If not, collect alarm information and configuration information, and then contact technical support personnel.