SRM/3/ENTITYINVALID: OID [OID] temperature chip exception. (EntityPhysicalIndex[INTEGER1], BaseTrapSeverity=[INTEGER2], BaseTrapProbableCause=[INTEGER3], BaseTrapEventType=[INTEGER4], EntPhysicalContainedIn=[INTEGER5], EntPhysicalName=[OCTET1], RelativeResource=[OCTET2], ReasonDescription=[OCTET3])
This alarm was generated when the chip was detected abnormal.
Alarm ID | Alarm Severity | Alarm Type |
---|---|---|
1.3.6.1.4.1.2011.5.25.129.2.1.9 | Minor | equipmentAlarm(5) |
Name | Meaning |
---|---|
oid | Indicates the MIB object ID of the alarm. |
EntityPhysicalIndex | Entity index. |
BaseTrapSeverity | Severity code. |
BaseTrapProbableCause | Error code. |
BaseTrapEventType | Code of the event type. |
EntPhysicalContainedIn | Entity code. |
EntPhysicalName | Entity name. |
RelativeResource | Name of the affected component. |
ReasonDescription | Fault description. |
The temperature of the board cannot be obtained. As a result, the fan module cannot automatically adjust the rotational speed according to the temperature of the board. The fan module thus keeps working at the full rotational speed with too much noise. The services, however, are not affected.
(1) If the character string "Read Temperature Fail" is displayed in the query result, it indicates that the IIC bus is faulty. In this case, you need to replace the device.
(2) If the character string "Read Temperature Fail" is not displayed in the query result, it indicates that the fault on the IIC bus is rectified. In this case, you need to go to Step 2.