Home
SRM/3/FANEXC
Message
SRM/3/FANEXC:Fault occurs in the fan in slot [ULONG].
Description
The fan does not work.
Parameters
Parameter Name
Parameter Meaning
ULONG
Indicates the slot ID of the fan.
Possible Causes
The fan hardware is faulty.
The fan is not installed properly.
Procedure
Run the
display fan
command to check whether the fan module is installed properly.
If so, go to step 2.
If not, install the fan properly.
Rectify the fault according to "
A Fan Fails
" in the
Troubleshooting Insights - Campus Switch - Hardware Fault
.