< Home

SRM/3/SUBCARD_CPLD_FAULT

Message

SRM/3/SUBCARD_CPLD_FAULT: CPLD is fault(Slot=[ULONG], Card=[ULONG]).

Description

The complex programmable logical device (CPLD) of a card does not work normally.

Parameters

Parameter Name Parameter Meaning
Slot Indicates a slot ID.
Card Indicates a card ID.

Possible Causes

The CPLD of a card is faulty.

Procedure

  1. Run the reset slot command to reset the fault board and check whether the log persists.
    • If so, go to step 2.
    • If not, the alarm handling ends.
  2. Replace the board and check whether the log persists.
    • If so, go to step 3.
    • If not, the alarm handling ends.
  3. Collect log information and configuration information, and then contact technical support personnel. You can collect diagnostic information using the display diagnostic-information command.