SRM/3/TXPOWER_EXCEEDMINOR:Optical module in interface [STRING] exception, Tx power is too low.
Description
The transmit power of an optical module is too low.
Parameters
Parameter Name
Parameter Meaning
STRING
Indicates an interface name.
Possible Causes
The transmit power of the optical module on the interface is below the lower threshold.
Procedure
Run the display transceiver command to check whether the transmit power (TX Power) of the optical module is below the lower threshold (TX Power Low Threshold).
If so, go to step 2.
If not, go to step 3.
Check whether the transmit power lower threshold of the optical module is within the acceptable range.
If so, run the transceiver diagnosis threshold tx-power command to change the transmit power lower threshold of the optical module.
If not, go to step 3.
Collect log information and configuration information, and then contact technical support personnel.You can collect diagnostic information using the display diagnostic-information command.