< Home

SRM/3/TXPOWER_EXCEEDMINOR

Message

SRM/3/TXPOWER_EXCEEDMINOR:Optical module in interface [STRING] exception, Tx power is too low.

Description

The transmit power of an optical module is too low.

Parameters

Parameter Name Parameter Meaning
STRING Indicates an interface name.

Possible Causes

The transmit power of the optical module on the interface is below the lower threshold.

Procedure

  1. Run the display transceiver command to check whether the transmit power (TX Power) of the optical module is below the lower threshold (TX Power Low Threshold).
    • If so, go to step 2.
    • If not, go to step 3.
  2. Check whether the transmit power lower threshold of the optical module is within the acceptable range.
    • If so, run the transceiver diagnosis threshold tx-power command to change the transmit power lower threshold of the optical module.
    • If not, go to step 3.
  3. Collect log information and configuration information, and then contact technical support personnel. You can collect diagnostic information using the display diagnostic-information command.
Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >