< Home

SW_SNPG/4/RPC_FAIL

Message

SW_SNPG/4/RPC_FAIL:Failed to send the configuration to LPU because of the failure of RPC. (Slot=[STRING])

Description

Configuration cannot be delivered because of RPC failure.

Parameters

Parameter Name Parameter Meaning
[STRING] Indicates the slot ID.

Possible Causes

  1. The board is not registered.

  2. The RPC channel is blocked.

Procedure

  1. Run the display device command to check whether the member switch has registered.

    • If so, go to step 3.
    • If not, go to step 2.

  2. If the member switch has not registered, RPC communication fails, which is normal. This log is informational only, and no action is required.
  3. Collect log information about RPC message sending failures of the member switch, and contact technical support personnel. You can collect diagnostic information using the display diagnostic-information command.