TRUNK/5/STATE_CHANGE: The working status of the Eth-Trunk in port-standby mode changed. (TrunkName=[STRING], Working port=[STRING], Status=[ULONG])
The working status of an Eth-Trunk interface in inter-board interface standby mode was changed. For example, the interface for data forwarding was changed from the master member interface to the backup member interface.
Parameter Name | Parameter Meaning |
---|---|
TrunkName |
Indicates the name of an Eth-Trunk interface in inter-board interface standby mode |
Working port |
Indicates the active member interface. |
Status |
Indicates the working status of an Eth-Trunk interface in inter-board interface standby mode |
1. The master interface for data forwarding was Down, and data was forwarded by the backup interface.
2. The master interface for data forwarding was deleted from the Eth-Trunk interface in inter-board interface standby mode, and data was forwarded by the backup interface.
3. The backup interface for data forwarding was Down, and data was forwarded by the master interface.
4. The protect-switch command was run to manually switch the active and inactive interfaces.
Check whether the master interface was purposely shut down.
If not, check the reason why the master interface was Down and ensure that the master interface is physically Up.
The reasons may be that the shutdown command was run on the local or remote interface or the master interface was faulty.
Check whether the master interface was purposely deleted from the Eth-Trunk interface.
Check whether the backup interface was purposely shut down.
If not, check the reason why the master interface was Down and ensure that the backup interface is physically Up.
The reasons may be that the shutdown command was run on the local or remote interface or the master interface was faulty.