< Home

alarm ip-used percentage

Function

The alarm ip-used percentage command configures the percentage of the alarms indicating that the addresses in an address pool are used up, and the percentage of the clear alarms.

The undo alarm ip-used percentage command restores the default percentages of the alarms and clear alarms.

By default, the percentage of the alarms indicating that the addresses in an IP address pool are used up is 100%, and the percentage of the clear alarms is 50%.

Format

alarm ip-used percentage alarm-resume-percentage alarm-percentage

undo alarm ip-used percentage

Parameters

Parameter

Description

Value

alarm-resume-percentage Specifies the percentage of the clear alarms. The value is an integer that ranges from 1 to 100. The default value is 50.
NOTE:
The percentage of the clear alarms cannot exceed that of the alarms.
alarm-percentage Specifies the percentage of the alarms indicating that the addresses in an address pool are used up. The value is an integer that ranges from 1 to 100. The default value is 100.

Views

IP address pool view

Default Level

2: Configuration level

Usage Guidelines

Usage Scenario

When the addresses in an IP address pool are used up, alarms are sent to notify the administrator.

Precautions

The percentage of the clear alarms cannot exceed that of the alarms.

Example

# Configure the percentage of the alarms indicating that the addresses in an address pool are used up, and the percentage of the clear alarms in the IP address pool view.

<HUAWEI> system-view
[HUAWEI] ip pool p1
[HUAWEI-ip-pool-p1] alarm ip-used percentage 80 90
Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >