The ap data-collection interval command sets the data buffer duration.
The undo ap data-collection interval command restores the default data buffer duration.
By default, an AC buffers AP data for 5 minutes.
ap data-collection interval interval
undo ap data-collection interval
Parameter
Description
Value
Specifies the buffer duration.
The value is an integer that ranges from 5 to 60, in minutes.
WLAN view
2: Configuration level
You can run the ap data-collection interval command to set the buffer duration.
# Enable an AC to buffer AP data and set the buffer duration.
<HUAWEI> system-view [HUAWEI] wlan [HUAWEI-wlan-view] ap data-collection enable [HUAWEI-wlan-view] ap data-collection interval 57