authentication timer arp handshake-period

Function

The authentication timer arp handshake-period command sets the handshake interval of the device with pre-connection users and authorized users.

The undo authentication timer arp command restores the default setting.

The default handshake interval of the device with pre-connection users and authorized users is 300 seconds.

Format

authentication timer arp handshake-period handshake-period

undo authentication timer arp

Parameters

Parameter

Description

Value

handshake-period

Specifies the handshake interval.

The value is an integer that ranges from 5 to 7200, in seconds.

Views

System view

Default Level

2: Configuration level

Usage Guidelines

This command is available to aid upgrade compatibility. It can only be run during the configuration restoration phase of the upgrade.

After the upgrade, this command is no longer supported, and it is replaced by the authentication timer handshake-period handshake-period command.