The clock priority command sets the priority of a clock source.
The undo clock priority command restores the default priority of a clock source.
By default, the priority of a clock source is 0.
Parameter | Description | Value |
---|---|---|
priority-value | Specifies the priority of a clock source. | The value is an integer that ranges from 1 to 255. A smaller value indicates a higher priority. |
By default, the priority of a clock source is 0, indicating that the clock source does not participate in clock source selection.
In automatic clock source selection mode, a clock source can participate in clock source selection only when a priority is configured. In manual and forcible clock source selection modes, clock source switching can be performed regardless of the clock source priority. In this case, whether a priority is configured does not affect the switching result. To set the priority of a clock source, run the clock priority command.