The clock source-lost holdoff-time command configures the holdoff time for the system to consider a clock source lost.
By default, the holdoff time for the system to consider a clock source lost is 1000 ms.
Parameter | Description | Value |
---|---|---|
value | Specifies the holdoff time for the system to consider a clock source lost. |
The value is an integer that ranges from 300 to 1800, in milliseconds. |
The system considers a clock source lost after a specified holdoff time. Within this period, the system considers that the clock source exists. Setting the holdoff time can avoid some mistakes in determining the clock source caused by occasional signal jitter on the network. To set the holdoff time for the system to consider a clock source lost, run the clock source-lost holdoff-time command.
If clock source switching needs to be implemented as soon as possible, set holdoff-time to a small value. To prevent frequent clock source switching, set holdoff-time to a large value.