This section provides a sample of setting the level of AIS PDUs to be sent using the edit-config method.
Operation |
XPATH |
---|---|
edit-config |
|
Item |
Data |
Description |
---|---|---|
MD name |
md_test |
Set the MD name to md_test. |
MA name |
ma_test |
Set the MA name to ma_test. |
Set the level of AIS PDUs to be sent. |
6 |
Set the level of AIS PDUs to be sent to 6. |
<?xml version='1.0' encoding='UTF-8'?> <rpc message-id="7" xmlns="urn:ietf:params:xml:ns:netconf:base:1.0"> <edit-config> <target> <running/> </target> <config> <huawei-cfm:cfm xmlns:huawei-cfm="urn:huawei:params:xml:ns:yang:huawei-cfm"> <huawei-cfm:md> <huawei-cfm:md-name>md_test</huawei-cfm:md-name> <huawei-cfm:ma> <huawei-cfm:ma-name>ma_test</huawei-cfm:ma-name> <huawei-cfm:ais> <huawei-cfm:level>6</huawei-cfm:level> </huawei-cfm:ais> </huawei-cfm:ma> </huawei-cfm:md> </huawei-cfm:cfm> </config> </edit-config> </rpc>
Sample of successful response
<rpc-reply xmlns="urn:ietf:params:xml:ns:netconf:base:1.0" message-id="7"> <ok/> </rpc-reply>
Sample of failed response
<?xml version='1.0' encoding='UTF-8'?> <rpc-reply xmlns="urn:ietf:params:xml:ns:netconf:base:1.0" message-id="7"> <rpc-error> <error-type>application</error-type> <error-tag>operation-failed</error-tag> <error-severity>error</error-severity> <error-message>parse rpc config error.</error-message> </rpc-error> </rpc-reply>