< Home

Configuring EFM Remote Loopback

This section provides a sample of configuring EFM remote loopback using the rpc method.

Table 1 Configuring EFM remote loopback

Operation

XPATH

rpc

  • /huawei-efm/remote-loopback/operate-type

  • /huawei-efm/remote-loopback/timeout

  • /huawei-efm/remote-loopback/interface

Data Requirements

Item

Data

Description

EFM remote loopback

start

Initiate EFM remote loopback.

Timeout interval for EFM remote loopback

0

Set the timeout interval for EFM remote loopback to 0.

Interface name

GigabitEthernet0/0/1

Specify the interface that needs to be configured with EFM remote loopback.

Request Example

<?xml version="1.0" encoding="UTF-8"?>
<rpc xmlns="urn:ietf:params:xml:ns:netconf:base:1.0" message-id="53">
  <huawei-efm:remote-loopback xmlns:huawei-efm="urn:huawei:params:xml:ns:yang:huawei-efm">
    <huawei-efm:operate-type>start</huawei-efm:operate-type>
    <huawei-efm:timeout>0</huawei-efm:timeout>
    <huawei-efm:interface>GigabitEthernet0/0/1</huawei-efm:interface>
  </huawei-efm:remote-loopback>
</rpc>

Response example

Sample of successful response

<?xml version='1.0' encoding='UTF-8'?>
<rpc-reply xmlns="urn:ietf:params:xml:ns:netconf:base:1.0" message-id="53">
  <ok/>
</rpc-reply>

Sample of failed response

</rpc-reply>
<?xml version='1.0' encoding='UTF-8'?>
<rpc-reply xmlns="urn:ietf:params:xml:ns:netconf:base:1.0" message-id="53">
  <rpc-error>
    <error-message>valid user-defined rpc fail.</error-message>
  </rpc-error>
</rpc-reply>