The configuration model file matching eMDI management is huawei-emdi.yang.
Object |
Description |
Value | Remarks |
---|---|---|---|
/emdi:emdi/emdi:emdi-enables/emdi:emdi-enable/emdi:emdi-enable |
Enables eMDI. |
The value is enable. |
Before disabling eMDI, stop the running eMDI instance first. |
/emdi:emdi/emdi:emdi-enables/emdi:emdi-enable/emdi:emdi-instances/emdi:emdi-instance/emdi:emdi-instance-id |
Creates an eMDI instance. |
The value is an integer in the range from 1 to 4096. |
Before deleting an eMDI instance, stop it first. |
/emdi:emdi/emdi:emdi-enables/emdi:emdi-enable/emdi:emdi-instances/emdi:emdi-instance/emdi:monitor-period |
Specifies an eMDI monitoring interval. |
The value is an integer, which can be 10, 30, or 60, in seconds. |
N/A |
/emdi:emdi/emdi:emdi-enables/emdi:emdi-enable/emdi:emdi-instances/emdi:emdi-instance/emdi:rtplr-threshold |
Specifies the alarm threshold of the packet loss rate for RTP packets transported over UDP. |
The value is an integer in the range from 1 to 100000. |
Before specifying this parameter, configure a target flow whose protocol type is UDP. |
/emdi:emdi/emdi:emdi-enables/emdi:emdi-enable/emdi:emdi-instances/emdi:emdi-instance/emdi:rtpser-threshold |
Specifies the alarm threshold of the out-of-order rate for RTP packets transported over UDP. |
The value is an integer in the range from 1 to 100000. |
Before specifying this parameter, configure a target flow whose protocol type is UDP. |
/emdi:emdi/emdi:emdi-enables/emdi:emdi-enable/emdi:emdi-instances/emdi:emdi-instance/emdi:uplr-threshold |
Specifies the alarm threshold of the upstream TCP packet loss rate. |
The value is an integer in the range from 1 to 100000. |
Before specifying this parameter, configure a target flow whose protocol type is TCP. |
/emdi:emdi/emdi:emdi-enables/emdi:emdi-enable/emdi:emdi-instances/emdi:emdi-instance/emdi:dplr-threshold |
Specifies the alarm threshold of the downstream TCP packet loss rate. |
The value is an integer in the range from 1 to 100000. |
Before specifying this parameter, configure a target flow whose protocol type is TCP. |
/emdi:emdi/emdi:emdi-enables/emdi:emdi-enable/emdi:emdi-instances/emdi:emdi-instance/emdi:source-ip-address |
Specifies the source IP address of a target flow. |
The value is in dotted decimal notation. |
N/A |
/emdi:emdi/emdi:emdi-enables/emdi:emdi-enable/emdi:emdi-instances/emdi:emdi-instance/emdi:destination-ip-address |
Specifies the destination IP address of a target flow. |
The value is in dotted decimal notation. |
N/A |
/emdi:emdi/emdi:emdi-enables/emdi:emdi-enable/emdi:emdi-instances/emdi:emdi-instance/emdi:ip-protocol-id |
Specifies the protocol type of a target flow. |
The value is of the enumerated type:
|
N/A |
/emdi:emdi/emdi:emdi-enables/emdi:emdi-enable/emdi:emdi-instances/emdi:emdi-instance/emdi:source-port |
Specifies the source port number of a target flow. |
The value is an integer in the range from 1 to 65535. |
N/A |
/emdi:emdi/emdi:emdi-enables/emdi:emdi-enable/emdi:emdi-instances/emdi:emdi-instance/emdi:destination-port |
Specifies the destination port number of a target flow. |
The value is an integer in the range from 1 to 65535. |
NA |
/emdi:emdi/emdi:emdi-enables/emdi:emdi-enable/emdi:emdi-instances/emdi:emdi-instance/emdi:vlan-id |
Specifies the VLAN ID of a target flow. |
The value is an integer in the range from 1 to 4094. |
N/A |
/emdi:emdi/emdi:emdi-enables/emdi:emdi-enable/emdi:emdi-instances/emdi:emdi-instance/emdi:pt-value |
Specifies the payload type of a target flow. |
The value is an integer in the range from 25 to 127. |
This parameter can be configured only for target flows transported over UDP. |
/emdi:emdi/emdi:emdi-enables/emdi:emdi-enable/emdi:emdi-instances/emdi:emdi-instance/emdi:clock-rate |
Specifies the clock rate of a target flow. |
The value is of the enumerated type:
|
This parameter can be configured only for target flows transported over UDP. |
/emdi:emdi/emdi:emdi-enables/emdi:emdi-enable/emdi:emdi-instances/emdi:emdi-instance/emdi:duration |
Specifies the lifetime of an eMDI instance. |
The value is an integer in the range from 300 to 604800. |
An eMDI instance automatically stops when its lifetime expires. |
/emdi:emdi/emdi:emdi-enables/emdi:emdi-enable/emdi:emdi-instances/emdi:emdi-instance/emdi:auto-start |
Specifies whether to start the current eMDI instance. |
The value is of the Boolean type:
|
N/A |
/huawei-emdi:flow-switch/input/instance-id |
Specifies the eMDI instance started in RPC messages. |
The value is an integer in the range from 1 to 4096. |
The value must be an existing eMDI instance. |
/huawei-emdi:flow-switch/input/start |
Starts an eMDI instance. |
- |
Before starting an eMDI instance, you must configure a target flow. |
/huawei-emdi:flow-switch/input/stop |
Stops an eMDI instance. |
- |
N/A |