< Home

Data Model

The configuration model file matching eMDI management is huawei-emdi.yang.

Table 1 eMDI management

Object

Description

Value Remarks

/emdi:emdi/emdi:emdi-enables/emdi:emdi-enable/emdi:emdi-enable

Enables eMDI.

The value is enable.

Before disabling eMDI, stop the running eMDI instance first.

/emdi:emdi/emdi:emdi-enables/emdi:emdi-enable/emdi:emdi-instances/emdi:emdi-instance/emdi:emdi-instance-id

Creates an eMDI instance.

The value is an integer in the range from 1 to 4096.

Before deleting an eMDI instance, stop it first.

/emdi:emdi/emdi:emdi-enables/emdi:emdi-enable/emdi:emdi-instances/emdi:emdi-instance/emdi:monitor-period

Specifies an eMDI monitoring interval.

The value is an integer, which can be 10, 30, or 60, in seconds.

N/A

/emdi:emdi/emdi:emdi-enables/emdi:emdi-enable/emdi:emdi-instances/emdi:emdi-instance/emdi:rtplr-threshold

Specifies the alarm threshold of the packet loss rate for RTP packets transported over UDP.

The value is an integer in the range from 1 to 100000.

Before specifying this parameter, configure a target flow whose protocol type is UDP.

/emdi:emdi/emdi:emdi-enables/emdi:emdi-enable/emdi:emdi-instances/emdi:emdi-instance/emdi:rtpser-threshold

Specifies the alarm threshold of the out-of-order rate for RTP packets transported over UDP.

The value is an integer in the range from 1 to 100000.

Before specifying this parameter, configure a target flow whose protocol type is UDP.

/emdi:emdi/emdi:emdi-enables/emdi:emdi-enable/emdi:emdi-instances/emdi:emdi-instance/emdi:uplr-threshold

Specifies the alarm threshold of the upstream TCP packet loss rate.

The value is an integer in the range from 1 to 100000.

Before specifying this parameter, configure a target flow whose protocol type is TCP.

/emdi:emdi/emdi:emdi-enables/emdi:emdi-enable/emdi:emdi-instances/emdi:emdi-instance/emdi:dplr-threshold

Specifies the alarm threshold of the downstream TCP packet loss rate.

The value is an integer in the range from 1 to 100000.

Before specifying this parameter, configure a target flow whose protocol type is TCP.

/emdi:emdi/emdi:emdi-enables/emdi:emdi-enable/emdi:emdi-instances/emdi:emdi-instance/emdi:source-ip-address

Specifies the source IP address of a target flow.

The value is in dotted decimal notation.

N/A

/emdi:emdi/emdi:emdi-enables/emdi:emdi-enable/emdi:emdi-instances/emdi:emdi-instance/emdi:destination-ip-address

Specifies the destination IP address of a target flow.

The value is in dotted decimal notation.

N/A

/emdi:emdi/emdi:emdi-enables/emdi:emdi-enable/emdi:emdi-instances/emdi:emdi-instance/emdi:ip-protocol-id

Specifies the protocol type of a target flow.

The value is of the enumerated type:
  • 6: transported over TCP
  • 17: transported over UDP

N/A

/emdi:emdi/emdi:emdi-enables/emdi:emdi-enable/emdi:emdi-instances/emdi:emdi-instance/emdi:source-port

Specifies the source port number of a target flow.

The value is an integer in the range from 1 to 65535.

N/A

/emdi:emdi/emdi:emdi-enables/emdi:emdi-enable/emdi:emdi-instances/emdi:emdi-instance/emdi:destination-port

Specifies the destination port number of a target flow.

The value is an integer in the range from 1 to 65535.

NA

/emdi:emdi/emdi:emdi-enables/emdi:emdi-enable/emdi:emdi-instances/emdi:emdi-instance/emdi:vlan-id

Specifies the VLAN ID of a target flow.

The value is an integer in the range from 1 to 4094.

N/A

/emdi:emdi/emdi:emdi-enables/emdi:emdi-enable/emdi:emdi-instances/emdi:emdi-instance/emdi:pt-value

Specifies the payload type of a target flow.

The value is an integer in the range from 25 to 127.

This parameter can be configured only for target flows transported over UDP.

/emdi:emdi/emdi:emdi-enables/emdi:emdi-enable/emdi:emdi-instances/emdi:emdi-instance/emdi:clock-rate

Specifies the clock rate of a target flow.

The value is of the enumerated type:
  • 8000 kHz
  • 16000 kHz
  • 90000 kHz

This parameter can be configured only for target flows transported over UDP.

/emdi:emdi/emdi:emdi-enables/emdi:emdi-enable/emdi:emdi-instances/emdi:emdi-instance/emdi:duration

Specifies the lifetime of an eMDI instance.

The value is an integer in the range from 300 to 604800.

An eMDI instance automatically stops when its lifetime expires.

/emdi:emdi/emdi:emdi-enables/emdi:emdi-enable/emdi:emdi-instances/emdi:emdi-instance/emdi:auto-start

Specifies whether to start the current eMDI instance.

The value is of the Boolean type:
  • true: Start the eMDI instance.
  • false: Do not start the eMDI instance.
The default value is false.

N/A

/huawei-emdi:flow-switch/input/instance-id

Specifies the eMDI instance started in RPC messages.

The value is an integer in the range from 1 to 4096.

The value must be an existing eMDI instance.

/huawei-emdi:flow-switch/input/start

Starts an eMDI instance.

-

Before starting an eMDI instance, you must configure a target flow.

/huawei-emdi:flow-switch/input/stop

Stops an eMDI instance.

-

N/A

Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
Next topic >