< Home

How Can I Determine Whether the Power Supply Status Is Abnormal?

The power supply status is abnormal in either of the following situations:
  1. Run the display power command to view the power supply status. If the State field displays NotSupply, the power module does not supply power. Check whether the power module is installed properly and whether the power switch is turned on.
    <HUAWEI> display power
    ------------------------------------------------------------
     Slot    PowerID  Online   Mode   State       Power(W)
    ------------------------------------------------------------
     0       PWR1     Present  AC     Supply      150.00
     0       PWR2     Present  AC     NotSupply   150.00  
  2. Run the display device command to view the power supply status. If the Status field displays Abnormal, the power supply status is abnormal. You can run the display trapbuffer command to check whether there are any power supply alarms.

    <HUAWEI> display device
    S5720-56C-PWR-EI-AC's Device status:
    Slot Sub  Type                Online    Power      Register     Status   Role
    -------------------------------------------------------------------------------
    0    -    S5720-56C-EI        Present   PowerOn    Registered   Normal    Standby
         1    ES5D21X02S01        Present   PowerOn    Registered   Normal    NA
         PWR1 POWER               Present   PowerOn    Registered   Normal    NA
         PWR2 POWER               Present   PowerOn    Registered   Abnormal NA
         FAN1 FAN                 Present   PowerOn    Registered   Normal    NA  

    Power supply alarms are as follows:

    SRM_1.3.6.1.4.1.2011.5.25.129.2.1.9 hwEntityInvalid 67966     //The power module is not powered on or has no electronic label loaded.
    SRM/3/POWERFAULT:OID [oid] Power is abnormal.( EntityPhysicalIndex=[INTEGER], BaseTrapSeverity=[INTEGER], BaseTrapProbableCause
    =[INTEGER], BaseTrapEventType=[INTEGER], EntPhysicalContainedIn=[INTEGER], EntPhysicalName=[OCTET], RelativeResource="[OCTET]",
     ReasonDescription="[OCTET]")
    ENTITYTRAP_1.3.6.1.4.1.2011.5.25.219.2.5.5 hwPowerInvalid    //The power module is abnormal.
    Entitytrap/1/POWERINVALID(t):OID [oid] Power supply is unavailable for some reason.(Index=[INTEGER], EntityPhysicalIndex=[INTEGER],
    PhysicalName=\"[OCTET]\", EntityTrapFaultID=[INTEGER])

For details about how to troubleshoot an abnormal power supply, see Power Supply Faults in the Troubleshooting - Hardware Troubleshooting.

Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
Next topic >