If non-Huawei-certified optical modules are used, the system may be unable to obtain the correct information. You are advised to use Huawei-certified optical modules.
Run the display transceiver interface interface-type interface-number verbose command to view power information of a specified optical module.
<HUAWEI> display transceiver interface gigabitethernet 0/0/1 verbose
GigabitEthernet0/0/1 transceiver information:
-------------------------------------------------------------
Common information:
Transceiver Type :GPS_SFP
Connector Type :SMA Coaxial Connector
Wavelength(nm) :-
Transfer Distance(m) :100(copper)
Digital Diagnostic Monitoring :NO
Vendor Name :HUAWEI
Vendor Part Number :HUAWEI AE 905S A
Ordering Name :
-------------------------------------------------------------
Manufacture information:
Manu. Serial Number :031TUX10HB000065
Manufacturing Date :2017-11-28
Vendor Name :HUAWEI
-------------------------------------------------------------
Diagnostic information:
Temperature(°C) :26.00
Temp High Threshold(°C) :85.00
Temp Low Threshold(°C) :-40.00
Voltage(V) :3.29
Volt High Threshold(V) :3.64
Volt Low Threshold(V) :2.95
Bias Current(mA) :4.57
Bias High Threshold(mA) :9.00
Bias Low Threshold(mA) :2.00
RX Power(dBM) :-40.00 //Indicate the current receive power of the optical module.
RX Power High Threshold(dBM) :0.00 //Indicate the receive power upper alarm threshold of the optical module.
RX Power Low Threshold(dBM) :-16.99 //Indicate the receive power lower alarm threshold of the optical module.
TX Power(dBM) :-5.03 //Indicate the current transmit power of the optical module.
TX Power High Threshold(dBM) :-2.22 //Indicate the transmit power upper alarm threshold of the optical module.
TX Power Low Threshold(dBM) :-6.99 //Indicate the transmit power lower alarm threshold of the optical module.
-------------------------------------------------------------
The optical power is normal when it is between the upper and lower thresholds. If the optical power exceeds the upper threshold, a high optical power alarm is generated. If the optical power falls below the lower threshold, a low optical power alarm is generated.