In a port connectivity check (port CC) scenario (no service is bound), an Eth-Trunk in LACP mode is configured on two devices. To ensure that services are not interrupted, associate the backup member interface of the Eth-Trunk in LACP mode with its primary member interface. If the primary link has poor quality, traffic is promptly switched to the standby link.
Only the S5720-HI, S5730-HI, S5731-H, S5731-S, S5731S-H, S5731S-S, S5732-H, S6720-HI, S6730-H, S6730S-H, S6730-S, and S6730S-S support this configuration.
The system view is displayed.
The primary member interface view of an Eth-Trunk's Actor is displayed.
Return to the system view.
The backup member interface view of an Eth-Trunk's Actor is displayed.
The backup member interface is associated with the primary member interface, and the priority of the backup member interface is dynamically changed.
When the primary link's quality recovers, run the lacp force-switch command in the Eth-Trunk interface view to enable forcible switching if no preemption is configured or preemption is enabled but the delay is not reached.